AW Test Directory
Customer Name
YYY Street
Anytown, NY 98745
The products listed below are eligible to bear the AW Test Mark and comply with the requirements of ANSI/CPLSO-14: 2016 (2021), Crane Insulators
Model | Type | Safe working mechanical load (SML) (Lbs) | Rated operating rms voltage (RO) (kV) | Frequency (Hz) | Routine proof test voltage (RTV) (kV) | Special Use Conditions |
---|---|---|---|---|---|---|
A | Insulating Link | 10,000 | 15 | 60 | 18 | None |
MARKINGS
Each insulator shall be clearly and indelibly marked with the name or trademark of the manufacturer, simplified operating instructions, the year of manufacture, design, unique serial number, weight, the safe working mechanical load (SML), the rated operating rms voltage (RO), operating frequency and the routine proof test voltage (RTV). Markings shall also include the maximum sustained operating temperature (MOT) and the minimum sustained operating temperature (MIT).